The Hazard Inside the Tank
Food and beverage plants are full of vessels: fermenters, bright beer tanks, syrup and blending tanks, CIP tanks, silos, hoppers and pits. Most of the time nobody goes inside them. When someone does, usually to inspect, repair or clean, they enter one of the most dangerous workplaces in industry. Confined space incidents have a grim pattern. The atmosphere overcomes the first person, and those who rush in to help become casualties too.
This guide explains what makes a space a confined space under Queensland law, why beverage plants carry particular risks, what must be in place before anyone enters and how good design removes the need to enter at all.
What a Confined Space Is
The definition is in Queensland’s Work Health and Safety Regulation 2011 and it has three parts. A confined space is an enclosed or partially enclosed space that is not designed or intended primarily to be occupied by a person, that is designed or intended to be at normal atmospheric pressure while a person is inside, and that is or is likely to be a risk to health and safety from one or more of four things.
Those four are an atmosphere that does not have a safe oxygen level, contaminants such as airborne gases, vapours and dusts that may cause injury from fire or explosion, harmful concentrations of any airborne contaminant, and engulfment.
Two points follow. A confined space is defined by its hazards, not its size. And the same vessel can change status. A tank that has been emptied, cleaned, ventilated and tested may present no atmospheric risk, while the same tank with residue in it does.
The Confined spaces Code of Practice 2021 lists where confined spaces are commonly found: vats, tanks, pits, pipes, ducts, silos, pressure vessels, sewers, wells and shafts. It also notes what generally is not one, including places designed for people to work in and enclosed spaces with ready ground level access such as cool stores.
Why Beverage Plants Carry Extra Risk
Carbon dioxide. Fermentation produces it, carbonation uses it and it is used to purge and blanket vessels. It is heavier than air, so it settles in the bottom of tanks, in pits and in low points, and it cannot be seen or smelled. It is harmful in its own right as well as displacing oxygen.
Nitrogen and other inert gases. Used for purging and blanketing, they displace oxygen without any warning sensation. A person entering an oxygen depleted space can lose consciousness within a breath or two.
Cleaning chemicals. CIP systems use caustic and acid solutions and sanitisers. Residues and vapours can remain in a vessel, and chemicals that are safe apart can react if mixed.
Engulfment. Silos and hoppers holding sugar, grain or malt can bury a person who steps onto a crust or a bridged surface.
Connected services. Tanks are connected to product lines, CIP supply, steam, gas and agitators. Any of these can introduce a hazard to someone inside if it is not isolated.
The code states that air normally contains 21 per cent oxygen by volume and that levels of 19.5 per cent to 23.5 per cent are considered safe. Outside that range, entry needs specific controls.
The First Duty Is to Avoid Entry
The regulation puts a duty on designers, manufacturers, importers and suppliers of plant and structures to eliminate the need to enter a confined space, so far as is reasonably practicable, and to eliminate the risk of inadvertent entry. Where that is not practicable, the need to enter must be minimised and the space designed with a safe means of entry and exit.
For a plant, the same thinking applies to every task that currently requires entry. Can it be done from outside? The code points to design features such as outlets and facilities for cleaning that eliminate the need for entry, lining materials that are durable and need minimal cleaning, and mechanical parts designed for safe and easy maintenance.
What Must Be in Place Before Anyone Enters
Where entry cannot be avoided, the regulation sets out specific requirements.
A written risk assessment. It must be carried out by a competent person and recorded in writing. It considers the atmosphere, the work to be done, the work methods and the emergency procedures needed. It must be reviewed when the risks change.
A confined space entry permit. Completed in writing by a competent person, it identifies the space, names the workers permitted to enter, states the period of validity and the control measures, and records when everyone has left and the work is complete.
Signs. Signs warning against entry by anyone other than those involved in the work must be placed at each entrance while the space is accessible.
Communication and a standby person. There must be continuous communication with the worker from outside the space, and a standby person in the vicinity to monitor conditions and, if practicable, observe the work.
Emergency procedures. First aid and rescue procedures must be established and practised, so that they are known to work before they are needed.
Training. Everyone involved, including those who issue permits, stand by and manage the work, must be trained in the hazards, the controls, the permit and the emergency procedures.
In practice these sit alongside atmospheric testing before and during entry, ventilation, and isolation of every service connected to the vessel.
The Standby Person and Rescue
The standby person’s role is to stay outside. They monitor the people inside, keep communication going, control who enters and raise the alarm. They do not go in.
That rule exists because of how confined space fatalities happen. The instinct to help a collapsed colleague is strong, and the atmosphere that felled the first person will fell the second just as quickly. Rescue must be planned to be carried out from outside wherever possible, with retrieval equipment rigged before entry. Anyone who has to enter for a rescue where the oxygen level is unsafe or contaminants are present needs air supplied respiratory protective equipment and the training to use it.
A plan that relies on calling emergency services is not a rescue plan. The time available is measured in minutes.
Records You Need to Keep
The risk assessment must be kept until at least 28 days after the work is completed. The entry permit must be kept until the work is completed. If a notifiable incident occurs, both must be kept for two years. Training records must be kept for two years.
Contractors Entering Your Tanks
Tank inspections, repairs and specialist cleaning are often contracted out. The contractor will bring its own procedures, but it does not know your plant. You know what was last in the vessel, which lines connect to it, what gases are used nearby and how your isolation system works. Sharing that information, agreeing who issues the permit and confirming the rescue arrangements before the day of the job are part of your duty as the business in control of the workplace.
If the work is construction work, such as structural repairs to a silo, working in or near a confined space is one of the categories of high risk construction work and a safe work method statement is also required.
Engineering the Entry Out
The most effective confined space control is not a better permit. It is not having to go in. In beverage plants the usual reasons for entry are cleaning, inspection and repair, and each can be reduced with engineering.
Clean in place systems with properly designed spray coverage remove the need for manual cleaning. Inspection ports, sight glasses and cameras allow internal checks from outside. Agitators, level probes and spray devices that can be withdrawn through a manway or a top nozzle can be serviced without anyone entering. Level and temperature instruments reduce the temptation to look inside.
It is worth listing every confined space entry your plant made last year and asking, for each, what change would have made it unnecessary.
Where BevTech Fits
BevTech is a family owned engineering business in Richlands, Brisbane, with more than 25 years in beverage and FMCG manufacturing. A good part of our work reduces the need for people to go where they should not have to. We design, automate and upgrade CIP systems, including a hot water rinse process for a can seamer controlled by a Siemens S7-1200, and we have automated glycol refrigeration for beer tank temperatures on a Siemens S7-1500. Our fabricators and machinists make the fittings and access modifications that let work be done from outside the vessel.
If there are tanks on your site that people still enter to clean or inspect, use the contact form at simonb307.sg-host.com/contact and we can look at whether that entry can be designed out.
This article is a general guide current as at October 2026 and is not a substitute for training or for the code of practice. Confirm the requirements for your workplace with Workplace Health and Safety Queensland.


Leave a Reply